Dynamic– in other words - Active pass boxes offer full protection by inflating themselves. We recommend this model especially for transferring products from a cleanroom to a non-cleanroom environment. They are an optimal choice in case your product might need to stay in the box for a longer period. Active boxes do not need any additional infrastructure because they already have everything built in that is needed for complex air handling. They also include a HEPA filter.
Model Versions | Dynamic standard | Dynamic combi | Dynamic 3-doors | Dynamic trolley |
![]() | ![]() | ![]() | ![]() | |
See image | See image | See image | See image | |
Dynamic model versions | ||||
---|---|---|---|---|
Standard | Combi | |||
3-doors | Trolley | |||
Outer dimensions w*d*h (mm) | 600*600*860 | 600*600*1760 | 600*600*860 | 900*900*1600 |
Inner dimensions w*d*h (mm) | 500*520*500 | 500*520*900/550 | 500*520*500 | 800*820*850 |
Material | AISI 316L Stainless steel /Anodized AL | AISI 316L Stainless steel /Anodised AL | AISI 316L Stainless steel /Anodised AL | AISI 316L Stainless steel /Anodised AL |
Custom size | ||||
No of doors | 2 | 2 | 3 | 2 |
Interlocking | / 3 doors | |||
Air system | With integrated fan and HEPA filter | With integrated fan and HEPA filter | With integrated fan and HEPA filter | With integrated fan and HEPA filter |
Recirculated air | ||||
Filtering | Yes, HEPA H13 | Yes, HEPA H13 | Yes, HEPA H13 | Yes, HEPA H13 |
Particle collection efficiency (%) | 99.95% | 99.95% | 99.95% | 99.95% |
Ducting | Integrated | Integrated | Integrated | Integrated |
Air drain valve | ||||
Shaping | Symmetrical shape for simple wall installation | Combi shape: for materials transfer on top and trolleys at the bottom | 3 doors shape: For wall connection of 3 different rooms | Special shape for trolleys, without a threshold |
Application | For ISO-14644/GMP clean rooms, laboratories. Clean – and high efficiency filtered material transfer solution between cleanroom environments, or between clean zone – outer rooms. | For ISO-14644/GMP clean rooms, laboratories. Clean – and high efficiency filtered transfer solution in case the wall surface is limited, but materials have to be moved by trolleys and manual transfer is also required. | For ISO-14644/GMP clean rooms, laboratories. Clean – and high efficiency filtered transfer solution where the cleanroom product need to be accessed from 3 different rooms. | For ISO-14644/GMP clean rooms, laboratories. Clean – and high efficiency filtered transfer solution in clean zones, where materials are moved by trolleys or carts. |
Standard fittings | -AISI 316L stainless steel body -Anodized Aluminum doors and box fronts -Durable, 3D adjustable hinges -Turnable hygienic S/S knob -Silicone sealed airtight joints -Glazed doors -Interlocking operation with remote switchboard -H13 HEPA filtering -Integrated brushless fan motor -Hidden air return channel | -AISI 316L stainless steel body -Anodized Aluminum doors and box fronts -Durable, 3D adjustable hinges -Turnable hygienic S/S knob -Silicone sealed airtight joints -Glazed doors -Interlocking operation with remote switchboard -H13 HEPA filtering -Integrated brushless fan motor -Hidden air return channel | -AISI 316L stainless steel body -Anodized Aluminum doors and box fronts -Durable, 3D adjustable hinges -Turnable hygienic S/S knob -Silicone sealed airtight joints -Glazed doors -Interlocking operation with remote switchboard -H13 HEPA filtering -Integrated brushless fan motor -Hidden air return channel | -AISI 316L stainless steel body -Anodized Aluminum doors and box fronts -Durable, 3D adjustable hinges -Turnable hygienic S/S knob -Silicone sealed airtight joints -Glazed doors -Interlocking operation with remote switchboard -H13 HEPA filtering -Integrated brushless fan motor -Hidden air return channel |
Power supply | 220 Volts / 50 Hz | 220 Volts / 50 Hz | 220 Volts / 50 Hz | 220 Volts / 50 Hz |
Interlocking voltage | 24V DC | 24V DC | 24V DC | 24V DC |
Options | ||||
UV-C Ultraviolet germicidal lamp | Available | Available | Available | Available |
Interlocking timer for UV-C lamp effectiveness | Available | Available | Available | Available |
Non-silicone version (sealed with Polymer) | Available | Available | Available | Available |
ATEX Zone II. explosion proof version (mechanical interlocking) | Available | Available | Available | Available |
Other | Adjustable feet for wall installation | Solid or grid type stainless steel divider between upper and lower chamber | Adjustable feet for wall installation | Fully solid doors |
LED lighting | Available | Available | Available | Available |
Powder coated body according to RAL colours | Available | Available | Available | Available |
Stainless steel bumpers | Available | Available | ||
Magnehelic pressure gauge | Available | Available | Available | Available |
Integrated DOP test ports | Available | Available | Available | Available |
Connection to building management systems | Available | Available | Available | Available |