Clean room requirements for pharmaceuticals: Key design, requirements, and innovations

28 May 2025
Clean room requirements for pharmaceuticals: Key design, requirements, and innovations

Pharma clean rooms are critical for protecting products and ensuring compliance. In this guide, you’ll learn the key clean room requirements for pharmaceuticals, ISO classifications, design best practices, and common mistakes to avoid. We’ll also cover new technologies that make clean rooms smarter and more efficient.

Requirements and standards for pharmaceutical clean rooms

Regulatory compliance is crucial in pharmaceutical cleanroom operations. Good Manufacturing Practices (GMP), FDA guidelines, and EU Annex 1 regulations mandate rigorous documentation, environmental monitoring protocols, and validation procedures.

Pharmaceutical cleanrooms must comply with a combination of international standards and regulatory guidelines that vary depending on the type of cleanroom and its intended use:

Cleanroom type Typical standards and regulations Notable remarks
Non-sterile pharmaceutical areas No mandatory EU GMP or PIC/S requirement for a formal "cleanroom" but use of clean areas with filtered air is common. Clean areas ventilated with filtered air to protect exposed products or containers; less stringent than sterile areas.
Particulate limits, gowning, and pressure cascades are defined based on risk.
Sterile pharmaceutical cleanrooms Must comply with EU GMP Annex 1 and PIC/S GMP guidelines, which include strict environmental, operational, and documentation requirements. EU GMP Annex 1 outlines detailed requirements beyond particle counts, including gowning, pressure differentials, and validation.
FDA GMP regulations in the US also apply, focusing on design, operation, and monitoring.
Pharmacy compounding cleanrooms (USP 797/800) Follow USP 797/800 guidelines for sterile and hazardous drug compounding. USP standards focus on compounding safety and sterility, with specific cleanroom classifications.
In the U.S., state pharmacy boards have final authority.
General cleanroom standards ISO 14644-1 defines cleanroom classifications based on airborne particle concentration limits, ranging from ISO Class 1 to ISO Class 9 ISO standards are globally accepted for classification and certification but do not cover all regulatory requirements.
ISO 14644 series covers design, operation, and monitoring.
WHO and other pharmacopeial guidelines provide additional operational guidance.

Designing an effective pharma clean room

When planning a pharmaceutical clean room, consider the following:

Key layout considerations

The clean room should have clear zones:

  • Grade A (or "clean zone") for high-risk operations such as filling and aseptic processing, often supported by laminar airflow to maintain unidirectional clean air.
  • Grade B zone for aseptic preparation and support areas.
  • Grades C and D for less critical manufacturing stages and general clean areas.

Separate pathways for staff and materials reduce contamination risks. Airlocks and pass-through chambers help maintain cleanliness during transfers.

Microbial control and sterility Requirements

  • Sterile cleanrooms are designed to achieve complete elimination of all microorganisms (bacteria, viruses, fungi, spores) to ensure sterility of products, especially for injectable drugs, ophthalmics, and other sterile pharmaceuticals. This requires strict microbiological control, sterilization processes, and continuous microbial monitoring.
  • Non-sterile cleanrooms focus on controlling particulate contamination (dust, particles) to protect product quality but do not guarantee sterility. They maintain cleanliness to reduce contamination risks for products like tablets, creams, and oral liquids.

Air filtration and airflow

HEPA filters remove 99.97% of airborne particles 0.3 microns in diameter, from the air. Laminar airflow directs clean air over critical work areas. Rooms need smooth, easy-to-clean surfaces with minimal equipment.

Sterile cleanrooms typically use HEPA or ULPA filters with laminar (unidirectional) airflow to create a highly controlled environment, often meeting ISO Class 5 or better in critical zones. The airflow is designed to sweep particles away from critical areas and maintain sterility.

Non-sterile cleanrooms use HEPA filtration as well but may operate at less stringent ISO classes (e.g., ISO 7 or 8) with turbulent or mixed airflow patterns sufficient to control particulate levels but not necessarily microbial sterility.

Smooth, easy-to-clean surfaces

Cleanroom surfaces must be smooth, impervious, and non-shedding to prevent particle generation and microbial growth. Materials like stainless steel and coated panels are commonly used because they resist corrosion, are easy to clean, and do not harbor contaminants.

HVAC systems: Temperature and humidity control

HVAC systems control temperature (18-24°C) and humidity (45-60%). Pressure differences between zones prevent contamination spread. Modern clean rooms use sensors to monitor air quality in real time.

clean room centralized vs decentralized AHU air handling unit

Layout of a clean room with a central HVAC system that controls to the lowest denominator and heats up the air locally

 

Pressure differentials

Maintaining proper pressure cascades between zones (with higher pressure in cleaner areas) helps prevent contamination from migrating from less clean to cleaner zones. This is achieved by controlling airflow and using sealed enclosures, often with airlocks as buffer zones.

Real-time air quality monitoring

Modern cleanrooms use sensors to continuously monitor air quality parameters such as particle counts, temperature, humidity, and pressure differentials. This real-time data ensures any deviations are detected immediately, helping to maintain product quality and comply with regulatory standards.

Common mistakes in cleanroom design

  1. Ignoring pressure cascade principles
    Incorrect pressure differentials can cause contamination migration. For example, positive pressure in dusty powder rooms can push particles outside the cleanroom.
  2. Poor airflow design
    Turbulent or insufficient airflow can lead to particle accumulation. Avoid designs that restrict airflow or create dead zones, such as overly wide laminar flow tunnels.
  3. Inadequate material selection
    Using materials that shed particles, are hard to clean, or degrade with disinfectants compromises cleanliness and increases maintenance costs.
  4. Overlooking personnel and material flow separation
    Mixing personnel and material pathways increases contamination risk. A lack of airlocks or pass through boxes can result in frequent door openings and contamination ingress.
  5. Neglecting real-time environmental monitoring
    Without continuous monitoring, deviations may go unnoticed, risking product quality and regulatory non-compliance.
  6. Insufficient space planning
    Cramped layouts hinder cleaning, maintenance, and personnel movement, increasing contamination risks and operational inefficiencies.
  7. Failing to plan for future changes
    Rigid designs without flexibility or modularity can lead to costly renovations or downtime when processes or products evolve.
  8. Inadequate gowning areas
    Poorly designed gowning rooms or improper gowning protocols can introduce contaminants into critical zones.

Pass box for safe material transfer in a pharma clean room 

Pass box for safe material transfer in a pharma clean room

Choosing a reliable clean room contractor

When selecting a clean room contractor, look for these qualities:

  • Experience and reliability: Choose companies with a strong history of clean room design and construction.
  • Cost awareness: Understand the full costs, including installation and ongoing maintenance.
  • Innovative solutions: Seek out technologies that can improve the performance of your clean room.

Current trends in pharmaceutical clean room design

The pharmaceutical clean room industry continues to evolve with technological advancements that promise to enhance both performance and sustainability.

Automation and digitalization

Automation trends are reducing human intervention in critical processes while improving consistency and compliance. AI-driven monitoring systems can now predict potential contamination events before they occur, allowing for proactive mitigation measures. The integration of smart sensors throughout clean room environments provides unprecedented visibility into operational conditions and system performance.

Advanced materials

Adoption of self-decontaminating surfaces, high-performance composites, electrostatic discharge-resistant materials, and nanocoatings is growing. These materials reduce surface contamination by up to 35%, extend component lifespan by 25%, and decrease cleaning time by 30%.

Sustainability

initiatives are reshaping clean room design and operation across the industry. Energy recovery ventilation systems, low-energy airflow designs, and recyclable construction materials are becoming standard considerations for new facilities.

Looking ahead

Developments in nanotechnology may lead to even more effective filtration solutions, while modular and mobile clean room concepts could revolutionize facility deployment timelines.

White dots

Get to know Kleanlabs competitive prices!
Ask for inquiry